夜城直播_夜城直播app官方正版下载_夜城直播高品质美女在线视频互动社区

黃岑:西門子PLC設(shè)備遠(yuǎn)程診斷那些事兒

2016/9/23 18:18:30 人評(píng)論 次瀏覽 分類:PLC應(yīng)用  文章地址:http://prosperiteweb.com/tech/1077.html

這是我的一次跨國(guó)遠(yuǎn)程技術(shù)服務(wù)中回復(fù)的郵件...... 
>Hi Cen,

>after adjustment belt tension on the capstan, the take up works properly.
>Thank you very much for your help.
> Regards! Kaz
 
----- Original Message -----
From: "Zane Huang"
To: "KM-ELECTRO Morski Kazimierz"
Sent: Monday, February 17, 2014 3:39 PM
Subject: Re: Take up 5/4
 
> Hi Kaz

> Long time haven't seen each other, miss you much.
> About the problem, I checked the historical data recorded in the system just now,
>and found some difference between take up #3 and take up #4.
> Pls see the attach files, screenshot pictures.
> It seems that the problem started from afternoon Feb. 10th.
> The take up system has auto-change function according to actual winding diameter of the reel.
> d = Vset/(Pi*RPMact)
> According to the recorded curves, the spool rotation speed must be much lower than it should
> be normally.
> Maybe this can help you solve the problem.
> Any further information, pls send it to me.
> Good luck !
> Huang Cen
 
-----Original Message-----
From: KM-ELECTRO Morski Kazimierz
Sent: Monday, February 17, 2014 7:16 PM
To: Zane Huang
Subject: Take up 5/4
 
> Hi Cen,

> Happy New Year!!!
> Have problems with take up 5/4.
> Random time 5-15 minutes to automatic spool change ( visible on LCD), take up change spool ,
> both on the left and right side...any ideas why?
> TeamViewer id: *********
> password: **********
> Best regards! Kaz
 
2014年的春節(jié)長(zhǎng)假剛過(guò)的一個(gè)周一,剛上班沒兩天,一切似乎還沉浸在假期的氣氛里,少有的清閑??煜掳嗲巴蝗唤拥揭粋€(gè)配套客戶主管工程師的電話,說(shuō)在12年出口波蘭的一套由我設(shè)計(jì)的設(shè)備出問(wèn)題無(wú)法生產(chǎn)了,當(dāng)?shù)氐墓こ處熋盍艘欢Y拜沒搞定,讓我準(zhǔn)備一下馬上去波蘭。氣氛一下有點(diǎn)小緊張,什么情況?設(shè)備的確是我設(shè)計(jì)的,也是我親自去波蘭調(diào)試的,那邊的設(shè)備主管Kaz也是個(gè)經(jīng)驗(yàn)豐富的老工程師,他協(xié)助我調(diào)試,臨走前我把家底兒都交代給他了,所以設(shè)備驗(yàn)收都快兩年了據(jù)說(shuō)一直不停地在生產(chǎn),從來(lái)沒找過(guò)我。怎么一下子就搞不定了呢?出啥大事兒啦?掛斷電話疑惑了幾分鐘,緊接著Kaz的郵件也到了,他描述了下故障的現(xiàn)象,并告訴我遠(yuǎn)程登錄設(shè)備的賬號(hào)密碼,當(dāng)年在調(diào)試的時(shí)候,Kaz就把設(shè)備控制系統(tǒng)的上位機(jī)(IPC547D有雙網(wǎng)卡)接入他們公司的網(wǎng)絡(luò),安裝了Teamviewer遠(yuǎn)程聯(lián)機(jī)軟件并做了測(cè)試,現(xiàn)在終于派上用場(chǎng)了。

事不宜遲,趕快登錄上去看看吧。打開了久違而又熟悉的畫面,設(shè)備一共4個(gè)工位,3個(gè)都在正常生產(chǎn),唯獨(dú)4號(hào)工位停機(jī)了,心定了,局部問(wèn)題,沒那么嚴(yán)重。接著,檢查了所有操作界面,參數(shù)界面,報(bào)警信息,系統(tǒng)診斷信息沒有發(fā)現(xiàn)任何的異常,甚至在歷史報(bào)警歸檔中都沒有找到一條有關(guān)于設(shè)備的故障信息,啥啥啥都是好好的嘛,搞什么鬼?轉(zhuǎn)念一想,以我對(duì)Kaz的了解,他是不會(huì)輕易瞎說(shuō)的,肯定是有問(wèn)題存在,但這時(shí)我也可以很自信地確定,故障與電氣控制系統(tǒng)之間應(yīng)該關(guān)系不大。一看時(shí)間,都7點(diǎn)多了,先下班回家吃飯吧。

一路上都在思考著問(wèn)題的各種可能性,回到家也是匆匆扒了幾口飯,就趕緊到書房打開電腦重新連線登錄了。又仔細(xì)過(guò)了一遍操作界面,參數(shù)界面,報(bào)警和診斷信息,歷史故障記錄,沒有發(fā)現(xiàn)任何有價(jià)值的信息,同時(shí)也再次確定控制系統(tǒng)沒有問(wèn)題。接著打開了生產(chǎn)過(guò)程工藝參數(shù)的歷史記錄,查看了4號(hào)工位的工況曲線,由于當(dāng)初在系統(tǒng)程序設(shè)計(jì)時(shí)特意留下了特征數(shù)據(jù),歷史歸檔數(shù)據(jù)也如實(shí)地記錄下并在曲線上反映了出來(lái),4號(hào)工位近2天的記錄的確如Kaz所述無(wú)法正常工作??吹竭@里我基本上明白了4號(hào)工位不能正常工作的原因,這是個(gè)高速線材收卷控制系統(tǒng),恒線速恒張力控制,系統(tǒng)設(shè)計(jì)有超卷徑保護(hù)功能,也就是當(dāng)實(shí)際工作線速度與實(shí)際收線軸轉(zhuǎn)速的比值在一段時(shí)間內(nèi)連續(xù)超過(guò)某個(gè)(滿卷)設(shè)定值時(shí),控制系統(tǒng)就會(huì)忽略計(jì)長(zhǎng)功能的計(jì)算值,從而直接自動(dòng)觸發(fā)自動(dòng)換卷功能。這功能是用來(lái)防止?jié)M卷再繞以及排線裝置出問(wèn)題后導(dǎo)致在一點(diǎn)固定卷繞的現(xiàn)象。但實(shí)際上4號(hào)工位都是在未滿卷狀態(tài)下就觸發(fā)了自動(dòng)換盤功能,唯一的解釋就是收卷軸的轉(zhuǎn)速低了,收線軸的折算線速度曲線對(duì)照也反映出了這個(gè)問(wèn)題。

3號(hào)工位正常的線速度曲線
                                        圖一:3號(hào)工位正常的線速度曲線

4號(hào)工位異常線速度曲線1
                                       圖二:4號(hào)工位異常線速度曲線1

4號(hào)工位異常線速度曲線2
圖三:4號(hào)工位異常線速度曲線2

究竟是什么導(dǎo)致收線軸轉(zhuǎn)速慢了,張力控制是正常的,難道是行線速度慢了?牽引是開環(huán)控制的,雖然我設(shè)計(jì)之初強(qiáng)烈要求采用閉環(huán)方案,但配套客戶還是以各種理由拒絕了,因此牽引的返回線速度實(shí)際是驅(qū)動(dòng)器斜坡函數(shù)的輸出值,這也是收線軸的線速度給定。我雖然強(qiáng)烈的懷疑,但沒有任何的證據(jù)可以證明牽引線速度出了問(wèn)題,再說(shuō)了線速度是重要的工藝參數(shù),對(duì)產(chǎn)品品質(zhì)有重大的影響,Kaz那邊也沒給我這方面的信息反饋,也只好放一放,從其他方向找原因了。

時(shí)間飛快的過(guò)去了,轉(zhuǎn)眼已是午夜了,還是沒有頭緒,雖然我很清楚電氣控制系統(tǒng)沒有問(wèn)題,但我也沒找到明確的證據(jù),明天讓我怎么跟客戶解釋呢?幾個(gè)小時(shí)的燒腦,讓我有些困了,這時(shí)突然網(wǎng)速一下子快了許多,遠(yuǎn)程端上位機(jī)的反應(yīng)也快了許多,我精神一振,把歷史曲線往前翻了很多天,發(fā)現(xiàn)4號(hào)工位的生產(chǎn)一直都是正常的,只是在一個(gè)星期前有過(guò)一次10幾個(gè)小時(shí)較長(zhǎng)時(shí)間的停機(jī)過(guò)程,再開機(jī)生產(chǎn)就不正常了,這期間發(fā)生了什么?還是先發(fā)個(gè)郵件問(wèn)問(wèn)Kaz吧,于是我就回了本文開頭的那封郵件…..

第二天,頂住了配套商打來(lái)的好幾通催促電話,也是在快下班前收到了Kaz的回復(fù),一切都明白了,我當(dāng)時(shí)最想做的就是把那個(gè)趾高氣昂的配套商主管工程師摁到馬桶里去,當(dāng)初就是他執(zhí)意否定牽引的閉環(huán)控制方案的….,問(wèn)題一解決,波蘭自然也就去不成了,還有點(diǎn)小可惜!

這純粹是一次偶然,也可以算是我正真意義上的對(duì)于設(shè)備直接做跨國(guó)遠(yuǎn)程技術(shù)診斷的一次實(shí)戰(zhàn)經(jīng)歷,在2年多前。時(shí)至今日,遠(yuǎn)程協(xié)助診斷與調(diào)試雖然已經(jīng)司空見慣,但這大多是在現(xiàn)場(chǎng)有人協(xié)助的,而遠(yuǎn)程直接面對(duì)機(jī)器設(shè)備的調(diào)試診斷其實(shí)并不如想象中的那么容易,幾個(gè)方面的準(zhǔn)備工作要做好,在下面詳細(xì)介紹:

遠(yuǎn)程直接面對(duì)機(jī)器設(shè)備的調(diào)試診斷的準(zhǔn)備工作
1、要有預(yù)先構(gòu)架好的網(wǎng)絡(luò),支持從Internet直接訪問(wèn)到客戶工廠里的設(shè)備。
現(xiàn)場(chǎng)設(shè)備有PC的,可以采用TEAMVIEWER等軟件通過(guò)遠(yuǎn)程桌面控制的方式進(jìn)行診斷和調(diào)試,現(xiàn)場(chǎng)PC通過(guò)客戶網(wǎng)絡(luò)能夠上網(wǎng),不需要固網(wǎng)IP地址(本案即此例)。
現(xiàn)場(chǎng)沒有PC的,可以通過(guò)采用VPN客戶端路由器、3G/4G移動(dòng)網(wǎng)絡(luò)、客戶的有線網(wǎng)絡(luò)以及VPN路由器服務(wù)器,把不在一地的PLC與工程師調(diào)試站拉到了同一個(gè)內(nèi)網(wǎng)中?,F(xiàn)場(chǎng)客戶端只要能上網(wǎng)即可,VPN路由器服務(wù)器側(cè)需要固網(wǎng)IP地址。
2、PLC及PC系統(tǒng)要配置有接入遠(yuǎn)程調(diào)試及診斷的通訊接口,應(yīng)盡量與用于現(xiàn)場(chǎng)設(shè)備通訊的接口分開及隔離。
3、有了以上的硬件條件后,設(shè)置并開通遠(yuǎn)程接入賬號(hào),事先做好連接測(cè)試,以備不時(shí)之需。
4、如果是到現(xiàn)場(chǎng)PC級(jí)的遠(yuǎn)程診斷(如本案),那么現(xiàn)場(chǎng)PC所能夠提供的設(shè)備信息就尤為重要了,這一般需要通過(guò)對(duì)現(xiàn)場(chǎng)的PC和PLC編程來(lái)實(shí)現(xiàn),通常都是將PLC上的信息都盡量傳送到現(xiàn)場(chǎng)的PC上,越全面越完善越好,這就需要事先周密地考慮與準(zhǔn)備。甚至現(xiàn)場(chǎng)PC也要安裝必要的編程組態(tài)軟件,通過(guò)遠(yuǎn)程桌面控制手段操作編程軟件對(duì)網(wǎng)絡(luò)中的PLC進(jìn)行調(diào)試診斷。

共有訪客發(fā)表了評(píng)論 網(wǎng)友評(píng)論

  客戶姓名:
郵箱或QQ:
驗(yàn)證碼: 看不清楚?